Follow
Lajos Höfler
Lajos Höfler
Verified email at mail.bme.hu
Title
Cited by
Cited by
Year
Hybridization-modulated ion fluxes through peptide-nucleic-acid-functionalized gold nanotubes. A new approach to quantitative label-free DNA analysis
G Jágerszki, RE Gyurcsányi, L Höfler, E Pretsch
Nano letters 7 (6), 1609-1612, 2007
1122007
FTIR‐ATR Study of Water Uptake and Diffusion Through Ion‐Selective Membranes Based on Plasticized Poly (vinyl chloride)
T Lindfors, F Sundfors, L Höfler, RE Gyurcsányi
Electroanalysis 21 (17‐18), 1914-1922, 2009
972009
Pre-polarized hydrophobic conducting polymer solid-contact ion-selective electrodes with improved potential reproducibility
N He, S Papp, T Lindfors, L Hofler, RM Latonen, RE Gyurcsanyi
Analytical chemistry 89 (4), 2598-2605, 2017
942017
FTIR-ATR study of water uptake and diffusion through ion-selective membranes based on poly (acrylates) and silicone rubber
F Sundfors, T Lindfors, L Höfler, R Bereczki, RE Gyurcsányi
Analytical chemistry 81 (14), 5925-5934, 2009
812009
Hyphenated FT-IR-Attenuated Total Reflection and Electrochemical Impedance Spectroscopy Technique to Study the Water Uptake and Potential Stability of Polymeric Solid-Contact …
T Lindfors, L Höfler, G Jágerszki, RE Gyurcsányi
Analytical chemistry 83 (12), 4902-4908, 2011
802011
Functional truncated membrane pores
D Stoddart, M Ayub, L Höfler, P Raychaudhuri, JW Klingelhoefer, ...
Proceedings of the National Academy of Sciences 111 (7), 2425-2430, 2014
772014
The Water Uptake of Plasticized Poly (vinyl chloride) Solid‐Contact Calcium‐Selective Electrodes
T Lindfors, F Sundfors, L Höfler, RE Gyurcsányi
Electroanalysis 23 (9), 2156-2163, 2011
572011
Limitations of Current Polarization for Lowering the Detection Limit of Potentiometric Polymeric Membrane Sensors
L Höfler, I Bedlechowicz, T Vigassy, RE Gyurcsányi, E Bakker, E Pretsch
Analytical chemistry 81 (9), 3592-3599, 2009
462009
Influence of Poly (3‐octylthiophene) on the Water Transport Through Methacrylic‐Acrylic Based Polymer Membranes
F Sundfors, L Höfler, RE Gyurcsányi, T Lindfors
Electroanalysis 23 (8), 1769-1772, 2011
422011
Detection of 3′-end RNA uridylation with a protein nanopore
M Clamer, L Höfler, E Mikhailova, G Viero, H Bayley
ACS nano 8 (2), 1364-1374, 2014
382014
Influence of hydrophobization of the polyazulene ion-to-electron transducer on the potential stability of calcium-selective solid-contact electrodes
N He, L Höfler, RM Latonen, T Lindfors
Sensors and Actuators B: Chemical 207, 918-925, 2015
332015
Nanosensors lost in space. A random walk study of single molecule detection with single-nanopore sensors
L Höfler, RE Gyurcsányi
Analytica chimica acta 722, 119-126, 2012
282012
Coarse Grained Molecular Dynamics Simulation of Electromechanically‐Gated DNA Modified Conical Nanopores
L Höfler, RE Gyurcsányi
Electroanalysis: An International Journal Devoted to Fundamental and …, 2008
262008
Electromodulated release of nitric oxide through polymer material from reservoir of inorganic nitrite salt
L Höfler, D Koley, J Wu, C Xi, ME Meyerhoff
RSC advances 2 (17), 6765-6767, 2012
252012
Lowering Detection Limits Toward Target Ions Using Quasi-Symmetric Polymeric Ion-Selective Membranes Combined with Amperometric Measurements
X Nagy, L Höfler
Analytical Chemistry 88 (19), 9850–9855, 2016
212016
Improved water barrier properties of polylactic acid films with an amorphous hydrogenated carbon (aC: H) coating
ZA Boeva, A Catena, L Höfler, S Wehner, CB Fischer, T Lindfors
Carbon 120, 157-164, 2017
192017
Electrocontrolled Swelling and Water Uptake of a Three‐Dimensional Conducting Polypyrrole Hydrogel
JL Antonio, L Höfler, T Lindfors, SI Córdoba de Torresi
ChemElectroChem 3 (12), 2146-2152, 2016
152016
Modeling the Effect of Oxygen on the Amperometric Response of Immobilized Organoselenium-Based S-Nitrosothiol Sensors
L Höfler, ME Meyerhoff
Analytical chemistry 83 (2), 619-624, 2011
112011
Nitric oxide delivery devices
ME Meyerhoff, L Hofler, D Koley, H Ren
US Patent 9,480,785, 2016
92016
Revisiting the response mechanism of polymeric membrane based heparin electrodes
AK Bell, L Höfler, ME Meyerhoff
Electroanalysis 24 (1), 53-59, 2012
82012
The system can't perform the operation now. Try again later.