Understanding the “demon’s algorithm”: 3D non-rigid registration by gradient descent X Pennec, P Cachier, N Ayache
International Conference on Medical Image Computing and Computer-Assisted …, 1999
412 1999 Iconic feature based nonrigid registration: the PASHA algorithm P Cachier, E Bardinet, D Dormont, X Pennec, N Ayache
Computer vision and image understanding 89 (2-3), 272-298, 2003
382 2003 Multisubject non-rigid registration of brain MRI using intensity and geometric features P Cachier, JF Mangin, X Pennec, D Riviere, D Papadopoulos-Orfanos, ...
Medical Image Computing and Computer-Assisted Intervention–MICCAI 2001: 4th …, 2001
152 2001 Fast non rigid matching by gradient descent: Study and improvements of the" demons" algorithm P Cachier, X Pennec, N Ayache
Inria, 1999
137 1999 Registration of 3D trans-esophageal echocardiography to X-ray fluoroscopy using image-based probe tracking G Gao, G Penney, Y Ma, N Gogin, P Cathier, A Arujuna, G Morton, ...
Medical image analysis 16 (1), 38-49, 2012
128 2012 Computer-aided detection (CAD) for CT colonography: a tool to address a growing need L Bogoni, P Cathier, M Dundar, A Jerebko, S Lakare, J Liang, ...
The British Journal of Radiology 78 (suppl_1), S57-S62, 2005
125 2005 Symmetrization of the non-rigid registration problem using inversion-invariant energies: Application to multiple sclerosis P Cachier, D Rey
International Conference on Medical Image Computing and Computer-Assisted …, 2000
110 2000 3D non-rigid registration by gradient descent on a Gaussian-windowed similarity measure using convolutions P Cachier, X Pennec
Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image …, 2000
103 2000 Computer-aided Detection of Colorectal Polyps: Can It Improve Sensitivity of Less-Experienced Readers? Preliminary Findings1 ME Baker, L Bogoni, NA Obuchowski, C Dass, RM Kendzierski, ...
Radiology 245 (1), 140-149, 2007
102 2007 Isotropic energies, filters and splines for vector field regularization P Cachier, N Ayache
Journal of Mathematical Imaging and Vision 20, 251-265, 2004
94 2004 Tracking brain deformations in time sequences of 3D US images X Pennec, P Cachier, N Ayache
Pattern Recognition Letters 24 (4-5), 801-813, 2003
91 2003 Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics R Maroy, R Boisgard, C Comtat, V Frouin, P Cathier, E Duchesnay, ...
IEEE transactions on medical imaging 27 (3), 342-354, 2008
86 2008 Elastic registration of electrophoresis images using intensity information and point landmarks K Rohr, P Cathier, S Wörz
Pattern recognition 37 (5), 1035-1048, 2004
74 2004 Real‐time x‐ray fluoroscopy‐based catheter detection and tracking for cardiac electrophysiology interventions YL Ma, N Gogin, P Cathier, RJ Housden, G Gijsbers, M Cooklin, M O'Neill, ...
Medical physics 40 (7), 071902, 2013
63 2013 Automated 2D‐3D registration of a radiograph and a cone beam CT using line‐segment enhancement a R Munbodh, DA Jaffray, DJ Moseley, Z Chen, JPS Knisely, P Cathier, ...
Medical physics 33 (5), 1398-1411, 2006
61 2006 Image representation supporting the accurate positioning of an intervention device in vessel intervention procedures R Florent, PYF Cathier, OP Nempont
US Patent 9,295,435, 2016
51 2016 Medical image computing and computer-assisted intervention–MICCAI’99 X Pennec, P Cachier, N Ayache, C Taylor, A Colchester
Springer, 1999
48 1999 Symmetric curvature patterns for colonic polyp detection A Jerebko, S Lakare, P Cathier, S Periaswamy, L Bogoni
International Conference on Medical Image Computing and Computer-Assisted …, 2006
42 2006 Connectivity-Based Parcellation of the Cortical Mantle Using -Ball Diffusion Imaging M Perrin, Y Cointepas, A Cachia, C Poupon, B Thirion, D Riviere, ...
International Journal of Biomedical Imaging 2008, 2008
40 2008 Nonrigid mr/us registration for tracking brain deformations X Pennec, N Ayache, A Roche, P Cathier
Multi-Sensor Image Fusion and Its Applications, 107-144, 2018
38 2018