Követés
Darvasi Eugen
Darvasi Eugen
Assoc. prof. dr., „Babeș-Bolyai” University, Faculty of Chemistry and Chemical Engineering
E-mail megerősítve itt: chem.ubbcluj.ro - Kezdőlap
Cím
Hivatkozott rá
Hivatkozott rá
Év
New method for mercury determination in microwave digested soil samples based on cold vapor capacitively coupled plasma microtorch optical emission spectrometry: comparison …
T Frentiu, AI Mihaltan, M Senila, E Darvasi, M Ponta, M Frentiu, ...
Microchemical Journal 110, 545-552, 2013
422013
Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry–comparison with inductively …
T Frentiu, S Butaciu, M Ponta, E Darvasi, M Senila, D Petreus, M Frentiu
Journal of Analytical Atomic Spectrometry 29 (10), 1880-1888, 2014
412014
Arsenic and antimony determination in non-and biodegradable materials by hydride generation capacitively coupled plasma microtorch optical emission spectrometry
AI Mihaltan, T Frentiu, M Ponta, D Petreus, M Frentiu, E Darvasi, ...
Talanta 109, 84-90, 2013
362013
Mercury determination in non-and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry
T Frentiu, AI Mihaltan, M Ponta, E Darvasi, M Frentiu, E Cordos
Journal of hazardous materials 193, 65-69, 2011
342011
Low power capacitively coupled plasma microtorch for simultaneous multielemental determination by atomic emission using microspectrometers
T Frentiu, D Petreus, M Senila, AI Mihaltan, E Darvasi, M Ponta, E Plaian, ...
Microchemical Journal 97 (2), 188-195, 2011
312011
Methylmercury determination in seafood by photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry
E Covaci, M Senila, M Ponta, E Darvasi, D Petreus, M Frentiu, T Frentiu
Talanta 170, 464-472, 2017
302017
Eco-scale non-chromatographic method for mercury speciation in fish using formic acid extraction and UV–Vis photochemical vapor generation capacitively coupled plasma …
E Covaci, SB Angyus, M Senila, M Ponta, E Darvasi, M Frentiu, T Frentiu
Microchemical Journal 141, 155-162, 2018
282018
Analytical characterization of a method for mercury determination in food using cold vapour capacitively coupled plasma microtorch optical emission spectrometry–compliance with …
T Frentiu, S Butaciu, E Darvasi, M Ponta, M Senila, D Petreus, M Frentiu
Analytical Methods 7 (2), 747-752, 2015
272015
A novel analytical system with a capacitively coupled plasma microtorch and a gold filament microcollector for the determination of total Hg in water by cold vapour atomic …
T Frentiu, AI Mihaltan, E Darvasi, M Ponta, C Roman, M Frentiu
Journal of Analytical Atomic Spectrometry 27 (10), 1753-1760, 2012
272012
Optical properties of PbS-CdS multilayers and mixed (CdS+ PbS) thin films deposited on glass substrate by spray pyrolysis
V Popescu, HI Nascu, E Darvasi
Journal of Optoelectronics and advanced Materials 8 (3), 1187, 2006
262006
A highly sensitive eco-scale method for mercury determination in water and food using photochemical vapor generation and miniaturized instrumentation for capacitively coupled …
E Covaci, M Senila, C Tanaselia, SB Angyus, M Ponta, E Darvasi, ...
Journal of Analytical Atomic Spectrometry 33 (5), 799-808, 2018
222018
A miniaturized capacitively coupled plasma microtorch optical emission spectrometer and a Rh coiled-filament as small-sized electrothermal vaporization device for simultaneous …
T Frentiu, E Darvasi, S Butaciu, M Ponta, D Petreus, AI Mihaltan, M Frentiu
Talanta 129, 72-78, 2014
222014
Mercury speciation in seafood using non-chromatographic chemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry method–Evaluation of …
E Covaci, M Senila, M Ponta, E Darvasi, M Frentiu, T Frentiu
Food Control 82, 266-273, 2017
202017
Determination of Cd in food using an electrothermal vaporization capacitively coupled plasma microtorch optical emission microspectrometer: Compliance with European legislation …
S Butaciu, T Frentiu, M Senila, E Darvasi, S Cadar, M Ponta, D Petreus, ...
Food Control 61, 227-234, 2016
202016
Sono-induced cold vapour generation interfaced with capacitively coupled plasma microtorch optical emission spectrometry: Analytical characterization and comparison with atomic …
T Frentiu, S Butaciu, E Darvasi, M Ponta, M Senila, E Levei, M Frentiu
Journal of Analytical Atomic Spectrometry 30 (5), 1161-1168, 2015
202015
Evaluation of figures of merit for Zn determination in environmental and biological samples using EDL excited AFS in a new radiofrequency capacitively coupled plasma
T Frentiu, M Ponta, M Senila, AI Mihaltan, E Darvasi, M Frentiu, E Cordos
Journal of Analytical Atomic Spectrometry 25 (5), 739-742, 2010
202010
Preliminary investigation of a medium power argon radiofrequency capacitively coupled plasma as atomization cell in atomic fluorescence spectrometry of cadmium
T Frentiu, E Darvasi, M Senila, M Ponta, E Cordos
Talanta 76 (5), 1170-1176, 2008
202008
Determination of total mercury in fish tissue using a low-cost cold vapor capacitively coupled plasma microtorch optical emission microspectrometer: comparison with direct …
T Frentiu, S Butaciu, M Ponta, M Senila, E Darvasi, M Frentiu, D Petreus
Food analytical methods 8, 643-648, 2015
192015
Application of low-cost electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for simultaneous determination of Cd and Pb in …
T Frentiu, E Darvasi, S Butaciu, M Ponta, D Petreus, R Etz, M Frentiu
Microchemical Journal 121, 192-198, 2015
172015
Analytical capability of a medium power capacitively coupled plasma for the multielemental determination in multimineral/multivitamin preparations by atomic emission spectrometry
T Frentiu, M Ponta, E Darvasi, M Frentiu, E Cordos
Food chemistry 134 (4), 2447-2452, 2012
172012
A rendszer jelenleg nem tudja elvégezni a műveletet. Próbálkozzon újra később.
Cikkek 1–20