New method for mercury determination in microwave digested soil samples based on cold vapor capacitively coupled plasma microtorch optical emission spectrometry: comparison … T Frentiu, AI Mihaltan, M Senila, E Darvasi, M Ponta, M Frentiu, ... Microchemical Journal 110, 545-552, 2013 | 42 | 2013 |
Simultaneous determination of As and Sb in soil using hydride generation capacitively coupled plasma microtorch optical emission spectrometry–comparison with inductively … T Frentiu, S Butaciu, M Ponta, E Darvasi, M Senila, D Petreus, M Frentiu Journal of Analytical Atomic Spectrometry 29 (10), 1880-1888, 2014 | 41 | 2014 |
Arsenic and antimony determination in non-and biodegradable materials by hydride generation capacitively coupled plasma microtorch optical emission spectrometry AI Mihaltan, T Frentiu, M Ponta, D Petreus, M Frentiu, E Darvasi, ... Talanta 109, 84-90, 2013 | 36 | 2013 |
Mercury determination in non-and biodegradable materials by cold vapor capacitively coupled plasma microtorch atomic emission spectrometry T Frentiu, AI Mihaltan, M Ponta, E Darvasi, M Frentiu, E Cordos Journal of hazardous materials 193, 65-69, 2011 | 34 | 2011 |
Low power capacitively coupled plasma microtorch for simultaneous multielemental determination by atomic emission using microspectrometers T Frentiu, D Petreus, M Senila, AI Mihaltan, E Darvasi, M Ponta, E Plaian, ... Microchemical Journal 97 (2), 188-195, 2011 | 31 | 2011 |
Methylmercury determination in seafood by photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry E Covaci, M Senila, M Ponta, E Darvasi, D Petreus, M Frentiu, T Frentiu Talanta 170, 464-472, 2017 | 30 | 2017 |
Eco-scale non-chromatographic method for mercury speciation in fish using formic acid extraction and UV–Vis photochemical vapor generation capacitively coupled plasma … E Covaci, SB Angyus, M Senila, M Ponta, E Darvasi, M Frentiu, T Frentiu Microchemical Journal 141, 155-162, 2018 | 28 | 2018 |
Analytical characterization of a method for mercury determination in food using cold vapour capacitively coupled plasma microtorch optical emission spectrometry–compliance with … T Frentiu, S Butaciu, E Darvasi, M Ponta, M Senila, D Petreus, M Frentiu Analytical Methods 7 (2), 747-752, 2015 | 27 | 2015 |
A novel analytical system with a capacitively coupled plasma microtorch and a gold filament microcollector for the determination of total Hg in water by cold vapour atomic … T Frentiu, AI Mihaltan, E Darvasi, M Ponta, C Roman, M Frentiu Journal of Analytical Atomic Spectrometry 27 (10), 1753-1760, 2012 | 27 | 2012 |
Optical properties of PbS-CdS multilayers and mixed (CdS+ PbS) thin films deposited on glass substrate by spray pyrolysis V Popescu, HI Nascu, E Darvasi Journal of Optoelectronics and advanced Materials 8 (3), 1187, 2006 | 26 | 2006 |
A highly sensitive eco-scale method for mercury determination in water and food using photochemical vapor generation and miniaturized instrumentation for capacitively coupled … E Covaci, M Senila, C Tanaselia, SB Angyus, M Ponta, E Darvasi, ... Journal of Analytical Atomic Spectrometry 33 (5), 799-808, 2018 | 22 | 2018 |
A miniaturized capacitively coupled plasma microtorch optical emission spectrometer and a Rh coiled-filament as small-sized electrothermal vaporization device for simultaneous … T Frentiu, E Darvasi, S Butaciu, M Ponta, D Petreus, AI Mihaltan, M Frentiu Talanta 129, 72-78, 2014 | 22 | 2014 |
Mercury speciation in seafood using non-chromatographic chemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry method–Evaluation of … E Covaci, M Senila, M Ponta, E Darvasi, M Frentiu, T Frentiu Food Control 82, 266-273, 2017 | 20 | 2017 |
Determination of Cd in food using an electrothermal vaporization capacitively coupled plasma microtorch optical emission microspectrometer: Compliance with European legislation … S Butaciu, T Frentiu, M Senila, E Darvasi, S Cadar, M Ponta, D Petreus, ... Food Control 61, 227-234, 2016 | 20 | 2016 |
Sono-induced cold vapour generation interfaced with capacitively coupled plasma microtorch optical emission spectrometry: Analytical characterization and comparison with atomic … T Frentiu, S Butaciu, E Darvasi, M Ponta, M Senila, E Levei, M Frentiu Journal of Analytical Atomic Spectrometry 30 (5), 1161-1168, 2015 | 20 | 2015 |
Evaluation of figures of merit for Zn determination in environmental and biological samples using EDL excited AFS in a new radiofrequency capacitively coupled plasma T Frentiu, M Ponta, M Senila, AI Mihaltan, E Darvasi, M Frentiu, E Cordos Journal of Analytical Atomic Spectrometry 25 (5), 739-742, 2010 | 20 | 2010 |
Preliminary investigation of a medium power argon radiofrequency capacitively coupled plasma as atomization cell in atomic fluorescence spectrometry of cadmium T Frentiu, E Darvasi, M Senila, M Ponta, E Cordos Talanta 76 (5), 1170-1176, 2008 | 20 | 2008 |
Determination of total mercury in fish tissue using a low-cost cold vapor capacitively coupled plasma microtorch optical emission microspectrometer: comparison with direct … T Frentiu, S Butaciu, M Ponta, M Senila, E Darvasi, M Frentiu, D Petreus Food analytical methods 8, 643-648, 2015 | 19 | 2015 |
Application of low-cost electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for simultaneous determination of Cd and Pb in … T Frentiu, E Darvasi, S Butaciu, M Ponta, D Petreus, R Etz, M Frentiu Microchemical Journal 121, 192-198, 2015 | 17 | 2015 |
Analytical capability of a medium power capacitively coupled plasma for the multielemental determination in multimineral/multivitamin preparations by atomic emission spectrometry T Frentiu, M Ponta, E Darvasi, M Frentiu, E Cordos Food chemistry 134 (4), 2447-2452, 2012 | 17 | 2012 |