Importance of the subscapularis muscle after total shoulder arthroplasty A Terrier, X Larrea, VM Camine, DP Pioletti, A Farron Clinical Biomechanics 28 (2), 146-150, 2013 | 62 | 2013 |
Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography VM Camine, HA Rüdiger, DP Pioletti, A Terrier International Orthopaedics, 1-9, 2017 | 33 | 2017 |
Impact of synovial fluid flow on temperature regulation in knee cartilage MN Moghadam, P Abdel-Sayed, VM Camine, DP Pioletti Journal of Biomechanics 48 (2), 370-374, 2015 | 31 | 2015 |
Comparison of an EMG-based and a stress-based method to predict shoulder muscle forces C Engelhardt, V Malfroy Camine, D Ingram, P Müllhaupt, A Farron, ... Computer methods in biomechanics and biomedical engineering 18 (12), 1272-1279, 2015 | 27 | 2015 |
Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers VM Camine, HA Rüdiger, DP Pioletti, A Terrier Journal of biomechanics 49 (16), 4002-4008, 2016 | 21 | 2016 |
Micromotion-induced peri-prosthetic fluid flow around a cementless femoral stem V Malfroy Camine, A Terrier, DP Pioletti Computer methods in biomechanics and biomedical engineering 20 (7), 730-736, 2017 | 8 | 2017 |
Distribution of gap and micromotion during compressive loading around a cementless femoral stem VM Camine, H Rüdiger, DP Pioletti, A Terrier Computer methods in biomechanics and biomedical engineering 18 (sup1), 1896-1897, 2015 | 4 | 2015 |
Biomechanical comparison of glenoid implants with adaptable and fixed backside curvatures in anatomic total shoulder arthroplasty A Terrier, R Obrist, VM Camine, F Becce, A Farron Journal of shoulder and elbow surgery 27 (9), 1656-1663, 2018 | 3 | 2018 |
Acromion index and supraspinatus muscle degeneration are positively correlated in patients undergoing reverse shoulder arthroplasty A Terrier, VM Camine, F Becce, A Farron Swiss Medical Weekly 148, 26S-26S, 2018 | | 2018 |
Micromotion and fluid flow around cementless femoral components in total hip arthroplasty VHE Malfroy Camine EPFL, 2016 | | 2016 |
In vitro measurement of micromotion around an uncemented fully coated femoral stem VM Camine, H Rudiger, D Pioletti, A Terrier SWISS MEDICAL WEEKLY 145, 38S-38S, 2015 | | 2015 |
A model for micromotion-induced fluid flow at the bone-implant interface VM Camine, D Pioletti, A Terrier Computer methods in biomechanics and biomedical engineering 17 (sup1), 52-53, 2014 | | 2014 |
Micromotion, subsidence and gap at the stem-femur interface after THA: a cadaveric study VM Camine, H Rudiger, P Bauduin, D Pioletti, A Terrier SWISS MEDICAL WEEKLY 143, 32S-32S, 2013 | | 2013 |
Sciper ID 174786 Affiliated labs LBO VM Camine, VM Camine, V Malfroy Camine | | |